Određivanje raspodjele doza u RTG dijagnostici na animalnom modelu (CROSBI ID 463328)

Prilog sa skupa u zborniku | stručni rad

Ranogajec-Komor, Maria ; Kulaš, Sandra ; Šimpraga, Miljenko ; Butković, V. ; Capak, D. ; Vekić, Branko Određivanje raspodjele doza u RTG dijagnostici na animalnom modelu // Zbornik radova Trećeg simpozija Hrvatskog društva za zaštitu od zračenja / Kubelka, Dragan ; Kovač, Jadranka (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1996. str. 191-197-x

Podaci o odgovornosti

Ranogajec-Komor, Maria ; Kulaš, Sandra ; Šimpraga, Miljenko ; Butković, V. ; Capak, D. ; Vekić, Branko

hrvatski

Određivanje raspodjele doza u RTG dijagnostici na animalnom modelu

The basis for radiation protection is the exact knowledge of absorbed dose. The dose determination in X-ray disagnostics is not a simple task because variable low-energy radiation has to be measured. Therefore the veterinarian X-ray equipment and the used dosimetric system were first tested and their reliability detemined. It was found that the dosimetric system used, i.e. the TLD-700 detectors combined with a computerized TOLEDO 654 reader meet the requirements of dose determination in the X-ray diagnostics. After determination of the uncertainty of the dosimetry system, of the irradiation field homogeneity and of the reproducibility of the X-ray irradiation procedure the organ doses received in X-ray examination of abdomen and pelvis of dogs were measured. The standard deviation of dose in the primary beam in 4 measurement cycles was +-5%, while the standard deviation of dose to organs was +- 25-30%. The analysis of the dosimetric results in the veterinarian X-ray diagnostics shows that besides the radiation damage the dose distribution (organ doses) can be estimated on the basis of the primary beam dose measurements.

nije evidentirano

nije evidentirano

engleski

Determination of dose distribution in the X-ray diagnostics using an animal (canine) model

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

191-197-x.

1996.

objavljeno

Podaci o matičnoj publikaciji

Zbornik radova Trećeg simpozija Hrvatskog društva za zaštitu od zračenja

Kubelka, Dragan ; Kovač, Jadranka

Zagreb: Hrvatsko društvo za zaštitu od zračenja

Podaci o skupu

Treći simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

20.11.1996-22.11.1996

Zagreb, Hrvatska

Povezanost rada

Kemija