The Flexible Taper Transitions for an In-Vacuum Undulator (CROSBI ID 516713)
Prilog sa skupa u zborniku | izvorni znanstveni rad
Podaci o odgovornosti
Reiser, Rudolf ; Zelenika, Saša ; Ingold, Gerhard ; Keller, Andreas ; Schultz, Lothar ; Hara, Toru ; Kitamura, Hideo
engleski
The Flexible Taper Transitions for an In-Vacuum Undulator
In a joint project between SPring-8 and PSI, an in-vacuum undulator U24 was installed in the SLS storage ring during 2001. In this frame, cooled flexible taper transitions were developed. Tests performed on a numerically optimized shape of the tapers have proven the validity of the adopted concept. In a further development step, a family of in-vacuum undulators is currently being designed. These will require an upgrade of the flexible tapers allowing a logitudinal degree of freedom based on a parallel spring translator mechanism. In this work the results of the optimized design of the taper assembly will be presented. A short description of the foreseen set-up being developed for the respective fatigue tests will follow. Depending on the outcome of the experimental assessment, the same concept could then be adopted also for a scraper device.
in-vacuum undulator; flexible taper; FEM analysis; fatigue tests
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
323-329-x.
2003.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of the 2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002)
Argonne (IL): ANL
Podaci o skupu
Nepoznat skup
predavanje
29.02.1904-29.02.2096