Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Framesaw operator exposure to the vibration (CROSBI ID 123734)

Prilog u časopisu | izvorni znanstveni rad

Goglia, Vlado ; Siklienka, Mikulaš ; Barcik, Štefan ; Grbac, Ivica ; Đukić, Igor Framesaw operator exposure to the vibration // Acta Facultatis Xylologiae Zvolen, 1 (2005), 21-32-x

Podaci o odgovornosti

Goglia, Vlado ; Siklienka, Mikulaš ; Barcik, Štefan ; Grbac, Ivica ; Đukić, Igor

engleski

Framesaw operator exposure to the vibration

The paper reports and analyses the results of vibration measurement carried out on a frame saw. Vibrations were measured on both the left and the right handle as well as on the operator’ s seat according to ISO 8662-8. The measured levels of the weighted accelerations of the vibration were compared to the daily exposure limits according to ISO 5349-1 and ISO 2631-1. Daily exposures were determined according to the same standards. The paper arose in collaboration with workers Faculty of Forestry Zagreb and Faculty of wood sciences and technology of Technical University in Zvolen.

Ergonomics; Health risk; Hand-arm vibration; Whole-body vibration; Exposure

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

1

2005.

21-32-x

objavljeno

1336-3824

Povezanost rada

Javno zdravstvo i zdravstvena zaštita, Šumarstvo