Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Optode membrane for continuous measurement of silver ions (CROSBI ID 127471)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Murković, Ivana ; Oehme, Ines ; Mohr, Gerhard J. ; Ferber, Tomislav ; Wolfbeis, Otto S. Optode membrane for continuous measurement of silver ions // Mikrochimica acta (1966), 121 (1995), 1-4; 249-258. doi: 10.1007/BF01248254

Podaci o odgovornosti

Murković, Ivana ; Oehme, Ines ; Mohr, Gerhard J. ; Ferber, Tomislav ; Wolfbeis, Otto S.

engleski

Optode membrane for continuous measurement of silver ions

An optical sensor (optode) membrane for continuous monitoring of silver ion is presented. It is composed of plasticized poly(vinyl chloride) (PVC), a silver- sensitive chromo-ionophore, and a lipophilic berate salt acting as an anionic site. The membrane selectively responds to silver ion in the concentration range from 50 mu M to 10 mM, giving a reversible colour change from blue to pink, with response times of the order of 2 min. The acridinium dye acts as both the recognition element and the chromo-ionophore. Its long-wave absorption band is at around 680 nm, which makes it compatible with existing LED light sources and diode lasers. A lipophilic octadecyl side chain renders it highly lipophilic and this prevents its leakage out of the PVC membrane. Hence, the operational lifetime exceeds 1 week, without any changes in the work function.

silver sensor ; optical sensors ; chromo-ionophore ; spectrophotometry ; PVC membrane

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

121 (1-4)

1995.

249-258

objavljeno

0026-3672

1436-5073

10.1007/BF01248254

Povezanost rada

Kemija

Poveznice
Indeksiranost