Evaluation of post-crack behaviour of polymer cement steel fibre reinforced concrete(PC-SFRC) (CROSBI ID 469975)

Prilog sa skupa u zborniku | stručni rad | međunarodna recenzija

Šušteršič, Jakob ; Ukrainczyk, Velimir ; Zajc, Andrej ; Šajna, Aljoša Evaluation of post-crack behaviour of polymer cement steel fibre reinforced concrete(PC-SFRC) // IXth International Congress on Polymers in Concrete / Sandrolini, Franco (ur.). Bolonja: RILEM, Gruppo Italiano Rilem, 1998. str. 409-417-x

Podaci o odgovornosti

Šušteršič, Jakob ; Ukrainczyk, Velimir ; Zajc, Andrej ; Šajna, Aljoša

engleski

Evaluation of post-crack behaviour of polymer cement steel fibre reinforced concrete(PC-SFRC)

Polymer cement steel fibre reinforced concrete (PC-SFRC) and steel fibre reinforced concrete (SFRC) specimens were tested according to WST (wedge splitting test) method. The age of concrete was 4 years. Specimens - cubes (10 x10 x10 cm) had initial notch length of 50 mm. During the test the load - COD (crack opening displacement) curve was recorded. But, due to fibres bridging the crack, it is very difficult to obtain complete area of the curve (absorption energy). Therefore, the load - COD curve is divided in four straight line segments, so that load decreases linearly to zero with increasing COD in the last segment. With such simplification, absorption energy of failure zone can be calculated as well as characteristic failure zone deformation. At the end, parameters for evaluation post-crack behaviour of PC-SFRC were calculated: ductility factor (1/B) and equivalent strengths up to crack widths of 0.1, 0.2, 0.3 and 0.4 mm. These parameters show improvement in the post-crack behaviour of SFRC when polymer is used.

polymer cement steel fibre reinforced concrete; wedge spliting test; post crack behaviour; ductility factor; equivalent strength

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

409-417-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Sandrolini, Franco

Bolonja: RILEM, Gruppo Italiano Rilem

Podaci o skupu

IXth International Congress on Polymers in Concrete

predavanje

14.09.1998-18.09.1998

Bologna, Italija

Povezanost rada

Građevinarstvo