A new criterion for treatement of cross-sections of structure members as thin-walled structures or thick-walled structures (CROSBI ID 83488)

Prilog u časopisu | izvorni znanstveni rad

Brnić, Josip A new criterion for treatement of cross-sections of structure members as thin-walled structures or thick-walled structures // Engineering review (Technical Faculty University of Rijeka), 16 (1996), 1-7-x

Podaci o odgovornosti

Brnić, Josip

engleski

A new criterion for treatement of cross-sections of structure members as thin-walled structures or thick-walled structures

A new criterion for treatment of cross-sections of structure members as thin-walled structures or thick-walled structures is presented. This criterion is based on the shear stress analysis using finite element method. Several finite elements are developed whose axial nodal displacements provide descirbing of cross-sectional warping. For one of them stiffness matrix and load vecotr in the case bending with shear are presented.

thin-walled structures; thick-walled structures; shear center; finite element method; computer

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

16

1996.

1-7-x

objavljeno

1330-9587

Povezanost rada

Strojarstvo