Seismic performance of the existing and newly designed wall buildings (CROSBI ID 523477)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Sigmund, Vladimir ; Guljaš, Ivica
engleski
Seismic performance of the existing and newly designed wall buildings
Buildings with reinforced concrete structural walls are frequently used in Croatia. Wall-to-floor ratio (at least in one direction) is usually high and although these walls were typically lightly reinforced with simple reinforcement details, such structures exhibited well behavior during previous earthquakes. Nevertheless, their analysis is usually quite complicated and time consuming at which end we find out that following minimum requirements were enough in the first place. The basic goal of this research was to simplify design and evaluation of structural wall buildings by introducing “ Performance domain” method as well as by the nonlinear static method N2 (as given in the Annex B of the Eurocode 8: Draft No 6, January 2003). Evaluation is performed on a chosen sample of wall buildings designed following minimum requirements according to the old HRN codes (for existing) and new seismic codes.
Rc wall buildings; seismic response; nonlinear analysis; performance based design
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
367-373-x.
2006.
objavljeno
Podaci o matičnoj publikaciji
Internacionalni naučno-stručni skup: Građevinarstvo- nauka i praksa
Lučić, Duško
Podgorica: Građevinski fakultet Univerziteta Crne Gore
Podaci o skupu
Internacionalni naučno - stručni skup Građevinarstvo - nauka i praksa
predavanje
20.02.2006-24.02.2006
Žabljak, Crna Gora