Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Leakage detection in power plant boiler (CROSBI ID 526399)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Bogdan, Željko ; Duić, Neven ; Schneider, Daniel-Rolph ; Šerman, Nikola ; Afgan, Naim Leakage detection in power plant boiler // Proceedings of 3rd European Conference on Industrial Furnaces and Boilers / Reis, Albino (ur.). 1995

Podaci o odgovornosti

Bogdan, Željko ; Duić, Neven ; Schneider, Daniel-Rolph ; Šerman, Nikola ; Afgan, Naim

engleski

Leakage detection in power plant boiler

The paper deals with the feasibility of using the radiation heat flux measurement as the diagnostic variable for the tube leakage detection system. The mathematical model based on the Monte Carlo zone method is used to investigate sensitivity of the radiative heat flux changes due to the water leakage into the furnace. Control volume based mathematical model is used to determine temperature, velocity and concentration fields. Radiative properties are determined by the three gray gases model. It was shown that the heat flux might be sufficiently sensitive diagnostic variable to be used in on-line monitoring of the large power plant boiler.

boiler tube leakage; Monte Carlo method; numerical simulation; mathematical modeling; combustion chamber

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1995.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of 3rd European Conference on Industrial Furnaces and Boilers

Reis, Albino

Podaci o skupu

3rd European Conference on Industrial Furnaces and Boilers

poster

18.04.1995-21.04.1995

Lisabon, Portugal

Povezanost rada

Strojarstvo