TRANSFORMATOR ZA UZEMLJENJE I VLASTITU POTROŠNJU (CROSBI ID 534752)
Prilog sa skupa u zborniku | izvorni znanstveni rad | domaća recenzija
Podaci o odgovornosti
Kelemen, Tomislav ; Boras, Miljenko ; Tomšić, Ivan
hrvatski
TRANSFORMATOR ZA UZEMLJENJE I VLASTITU POTROŠNJU
Transformator za uzemljenje i vlastitu potrošnju u spoju ZNyn omogućuje uzemljenje izolirane trofazne mreže i napajanje vlastite potrošnje. Međutim, pri jednopolnom kratkom spoju na sekundaru, takav transformator se ponaša bitno drugačije nego uobičajeni transformator za vlastitu potrošnju u spoju Dyn, struja kvara je i do 5 puta manja, a naponi zdravih faza na sekundaru su za oko 50% veći od napona u praznom hodu. Ako se transformatoru za uzemljenje doda stabilizacijski namot te razlike prema transformatoru u spoju Dyn nestaju. U referatu se na osnovi računa i mjerenja na realnom transformatoru izgrađuje fizikalna slika o pojavama u transformatoru za uzemljenje i vlastitu potrošnju pri jednopolnom kratkom spoju na sekundaru, za slučaj kada postoji stabilizacijski namot i za slučaj kada ga nema. Očigledno je da zaštita u jednom i drugom slučaju dobiva bitno različite informacije. Unatoč tomu, kupci traže transformatore za uzemljenje i vlastitu potrošnju sa stabilizacijskim namotom i bez njega, a postojeće norme ne upozoravaju na ovaj problem, niti propisuju mjerenja na osnovi kojih bi se dobile informacije potrebne za izbor zaštite. SUMMARY Earthing and auxiliary transformer in ZNyn connection provides both isolated network earthing and auxiliary consumption supply. However, in the case of phase-to-earth short circuit on secondary side such a transformer behaves fundamentally differently than the ones usually used for auxiliary consumption supply in Dyn connection - its short circuit current is up to 5 times lower, and healthy phase voltages are approximately 50% higher than voltages in the same phases in no load condition. If stabilization winding is added, these differences from transformers in Dyn connection disappear. Based on calculations and measurements performed on a real transformer, this paper presents a physical model of phenomena in an earthing and auxiliary transformer during phase-to-earth short circuit on secondary side, for both cases with and without the stabilization winding. It is obvious that in these two cases the protection system receives essentially different measurement values. Nevertheless, customers still demand earthing and auxiliary transformers with and without compensating winding, and the standards in effect do not point out this problem, not even prescribing measurements that would provide the information necessary for protection system design.
transformator za uzemljenje; transformator za vlastitu potrošnju; Z spoj; nulta
nije evidentirano
engleski
EARTHING AND AUXILIARY TRANSFORMER
nije evidentirano
earthing transformer; auxiliary transformer; interconnected star; zero sequence
nije evidentirano
Podaci o prilogu
1-8.
2007.
objavljeno
Podaci o matičnoj publikaciji
Mozer, Josip ; Tomiša, Irena
Zagreb: Hrvatski komitet međunarodne konferencije za velike električne sisteme (CIGRE)
Podaci o skupu
8. savjetovanje HRO CIGRE, Cavtat, 4.do 8. studenoga 2007.
predavanje
04.11.2007-08.11.2007
Cavtat, Hrvatska