Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Determination of florfenicol in plasma of pigs by high performance liquid chromatography (CROSBI ID 536306)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Logomerac, Vesna ; Terzić, Svjetlana ; Šandor, Ksenija Determination of florfenicol in plasma of pigs by high performance liquid chromatography // Abstracts of the 20th IPVS Congress / Evans, Peter (ur.). Durban, 2008. str. 482-482

Podaci o odgovornosti

Logomerac, Vesna ; Terzić, Svjetlana ; Šandor, Ksenija

engleski

Determination of florfenicol in plasma of pigs by high performance liquid chromatography

The objective of our experiment was to develop fast and efficient method for determination of florfenicol in plasma which could be used during pharmacokinetic studies.Method conduction on monolithic HPLC column of new generation, shorten elution time with extremely strong correlation of the results. Florfenicol plasma concentrations after application of Floron® ; ; ; ; ; and Nuflor® ; ; ; ; ; have almost the same absorption trends, but the statistical analysis shows significant differences in their elimination dynamics. Florfenicol concentration in pig plasma stays in method working range for six days after second administration of drugs in therapeutic dose.

florfenicol; pigs; plasma; HPLC

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

482-482.

2008.

objavljeno

Podaci o matičnoj publikaciji

Abstracts of the 20th IPVS Congress

Evans, Peter

Durban:

978-0-620-41364-0

Podaci o skupu

IPVS Congress (20 ; 2008)

poster

22.06.2008-26.06.2008

Durban, Južnoafrička Republika

Povezanost rada

Veterinarska medicina