Determination of cationic surfactants in pharmaceutical disinfectants using a new, highly sensitive potentiometric sensor (CROSBI ID 537631)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | domaća recenzija

Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan ; Galović, Olivera ; Sakač, Nikola ; Matešić-Puač, Ružica ; Grabarić, Zorana Determination of cationic surfactants in pharmaceutical disinfectants using a new, highly sensitive potentiometric sensor // 1st Regional Symposium on Electrochemistry of South-East Europe / Horvat-Radošević, Višnja ; Mandić, Zoran ; Gojo, Miroslav (ur.). Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008. str. 288-289

Podaci o odgovornosti

Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan ; Galović, Olivera ; Sakač, Nikola ; Matešić-Puač, Ružica ; Grabarić, Zorana

engleski

Determination of cationic surfactants in pharmaceutical disinfectants using a new, highly sensitive potentiometric sensor

A new sensitive potentiometric surfactant sensor was prepared based on a highly lipophilic 1, 3-didecyl-2-methyl-imidazolium (DMI) cation and a tetraphenylborate (TPB) antagonist ion. This compound was used as a sensing material and incorporated into the plasticized PVC-membrane. The sensor responded fast and showed a Nernstian response for all the investigated cationic surfactants: 59.8 mV/decade for cetylpyridinium chloride (CPC), 58.6 mV/decade for hexadecyltrimethylammonium bromide (CTAB), and 56.8 mV/decade for Hyamine. The sensor served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant, and displayed satisfactory analytical performances within a pH range of two to eleven. The influence of the ethoxylated alcohols (EONS), a widely used class of nonionic surfactants on the shape of titration curves was negligible if the mass ratio of EONS:CS was not greater than five. The selectivity coefficients were determined by fitting the Nikolskii-Eisenman equation to the experimental data obtained by the mixed solution method. The sensor exhibited excellent selectivity performances for CPC over all organic and inorganic cations investigated. Several commercial disinfectant products containing various cationic surfactants were potentiometrically titrated using the new DMI-TPB sensor as an indicator.

Potentiometric sensor; Cationic surfactants; Pharmaceutical disinfectants

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

288-289.

2008.

objavljeno

Podaci o matičnoj publikaciji

1st Regional Symposium on Electrochemistry of South-East Europe

Horvat-Radošević, Višnja ; Mandić, Zoran ; Gojo, Miroslav

Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI)

978-953-6894-33-8

Podaci o skupu

1st Regional Symposium on Electrochemistry of South-East Europe

poster

04.05.2008-08.05.2008

Rovinj, Hrvatska

Povezanost rada

Kemija