Diode in-vivo dosimetry for external beam radiotherapy: patient data analysis (CROSBI ID 540110)

Prilog sa skupa u zborniku | izvorni znanstveni rad | domaća recenzija

Mrčela, Iva ; Bokulić, Tomislav ; Budanec, Mirjana ; Frobe Ana ; Soldić, Željko ; Kusić, Zvonko Diode in-vivo dosimetry for external beam radiotherapy: patient data analysis // Proceedings of the Seventh Symposium of the Croatian Radiation Protection Association / Barišić, Delko ; Grahek, Željko ; Krajcar Bronić, Ines et al. (ur.). Zagreb, 2008. str. 190-197

Podaci o odgovornosti

Mrčela, Iva ; Bokulić, Tomislav ; Budanec, Mirjana ; Frobe Ana ; Soldić, Željko ; Kusić, Zvonko

engleski

Diode in-vivo dosimetry for external beam radiotherapy: patient data analysis

In-vivo dosimetry for radiotherapy patients became a part of routine quality assurance procedures at the UH “ Sestre milosrdnice” Department of Oncology and Nuclear Medicine. This is generally known as a very good tool for tracking and preventing possible errors in the radiotherapy chain. Semiconductor p-type silicon diodes are employed in the measurement of the dose delivered at the depth of maximum dose. Diodes are calibrated for the entrance dose measurements in a Co-60 beam and a set of correction factors is determined to account for non-reference clinical conditions. Protocol for the characterization of detectors and the implementation of in-vivo dosimetry was proposed within the research project coordinated by the International Atomic Energy Agency (IAEA). Before starting with patient measurements a series of verification setups and measurements were taken on the anthropomorphic Alderson phantom. Until now, there are about one thousand fields examined, mainly within first three fractions of the treatment. In this work we present patient data analysis in a view of different treatment parameters such as: localization, field type, gantry and surface angle, and the use of blocks and wedges. Statistical tests are used for objective investigation of the delivered dose accuracy in relation to the above mentioned treatment parameters.

in-vivo dosimetry; radiotherapy

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

190-197.

2008.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the Seventh Symposium of the Croatian Radiation Protection Association

Barišić, Delko ; Grahek, Željko ; Krajcar Bronić, Ines ; Miljanić, Saveta

Zagreb:

978-953-96133-6-3

Podaci o skupu

7th Symposium of the Croatian radiation Protection Association

predavanje

29.05.2008-31.05.2008

Opatija, Hrvatska

Povezanost rada

Fizika, Kliničke medicinske znanosti