Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Stud Arc Welding – Changes of the main welding parameters due to welding on unclean surface (CROSBI ID 542918)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Samardžić, Ivan ; Kolumbić, Zvonimir ; Klarić, Štefanija Stud Arc Welding – Changes of the main welding parameters due to welding on unclean surface // Abstracts of the Fourth International PhD, DLA Symposium / Mecsi, Josef (ur.). Pečuh: University of Pecs, Pollack Mihaly Faculty of Engineering, 2008. str. 30-31

Podaci o odgovornosti

Samardžić, Ivan ; Kolumbić, Zvonimir ; Klarić, Štefanija

engleski

Stud Arc Welding – Changes of the main welding parameters due to welding on unclean surface

The main purpose of welding parameters monitoring systems is to monitor the welding voltage and current in real time (on-line). This relies on experiences that useful information about welding process quality can be gained by analysis of welding voltage and current dynamics. However, some of the systems for welding process monitoring include, besides of welding current and voltage gauges, welding velocity and wire feed speed gauges (MAIG/MAG welding process) as well as temperature and gas flow gauges [1]. Systems for monitoring of main welding parameters are used for on-line monitoring of welding processes in manufacturing quality control, as a support in development of new filler metals, shielding gasses, and welding equipment, optimization of welding technology, adjusting of parameters and welding equipment characteristics as well as adaptive control of the welding process [2]. It is important to discover the welding parameters irregularities in real welding conditions so they can be eliminated in order to achieve acceptable weld quality. In this paper, the applicability of methods for stability evaluation usually used in MAG welding process [2, 3] for application on stud arc welding is analyzed.

Stud Arc Welding; On-line monitoring; Process stability

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

30-31.

2008.

objavljeno

Podaci o matičnoj publikaciji

Abstracts of the Fourth International PhD, DLA Symposium

Mecsi, Josef

Pečuh: University of Pecs, Pollack Mihaly Faculty of Engineering

978-963-7298-27-1

Podaci o skupu

Fourth International PhD, DLA Symposium

predavanje

20.10.2008-21.10.2008

Pečuh, Mađarska

Povezanost rada

Strojarstvo