Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Automated measurement with electrooptical distance meter and precise distance measurement processing at the calibration base of the faculty of geodesy in Zagreb (CROSBI ID 544144)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Solarić, Nikola ; Barković, Đuro ; Vučić, Nikola Automated measurement with electrooptical distance meter and precise distance measurement processing at the calibration base of the faculty of geodesy in Zagreb // Proceedings of the 1st International Symposium Regional Metrology Organizations (RMO 2008) "Metrology, Testing, and Accreditation – Breaking the Trading Barriers" and the 20th International Metrology Symposium / Ilić, Damir ; Boršić, Mladen ; Jurčević, Marko (ur.). Zagreb: Metrology Consulting, 2008. str. 224-226

Podaci o odgovornosti

Solarić, Nikola ; Barković, Đuro ; Vučić, Nikola

engleski

Automated measurement with electrooptical distance meter and precise distance measurement processing at the calibration base of the faculty of geodesy in Zagreb

The paper describes the method of setting the parameters in the instrument Leica TC 2003 before going to the Calibration base for the purpose of automated precise distance measurement. Software has been developed for the automated distance measurement data processing for seven pillars of the Calibration base.In data processing there are standard deviations of measured distance mean values obtained from the measurement forward and backward. After the processing and adjustment of measured values, definite pillar ranges are obtained, as well as the addition correction. Apart from that, there are standard deviations of distance mean values from the measurements forward and backward computed depending on the distance, then standard deviations in determining the pillar ranges and standard deviations in determining the addition correction.This automated measurements and the processing of measured data will enable regular periodical adjustment of the Calibration Base of the Faculty of Geodesy, University of Zagreb, in accordance with the Book of Rules on Standard maintenance.

Calibration base; standard adjustment.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

224-226.

2008.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 1st International Symposium Regional Metrology Organizations (RMO 2008) "Metrology, Testing, and Accreditation – Breaking the Trading Barriers" and the 20th International Metrology Symposium

Ilić, Damir ; Boršić, Mladen ; Jurčević, Marko

Zagreb: Metrology Consulting

978-953-95179-1-3

Podaci o skupu

International Symposium Regional Metrology Organizations "Metrology, Testing, and Accreditation - Breaking the Trading Barriers" (1 ; 2008) ; International Metrology Symposium (20 ; 2008)

predavanje

12.11.2008-15.11.2008

Dubrovnik, Hrvatska; Cavtat, Hrvatska

Povezanost rada

Geodezija