Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

SPE-HPLC/DAD determination of trimethoprim, oxytetracycline and enrofloxacin in water samples (CROSBI ID 147757)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ašperger, Danijela ; Babić, Sandra ; Mutavdžić Pavlović, Dragana ; Dolar, Davor ; Košutić, Krešimir ; Horvat, Alka J. M. ; Kaštelan-Macan, Marija SPE-HPLC/DAD determination of trimethoprim, oxytetracycline and enrofloxacin in water samples // International journal of environmental analytical chemistry, 89 (2009), 8-12; 809-819. doi: 10.1080/03067310902822896

Podaci o odgovornosti

Ašperger, Danijela ; Babić, Sandra ; Mutavdžić Pavlović, Dragana ; Dolar, Davor ; Košutić, Krešimir ; Horvat, Alka J. M. ; Kaštelan-Macan, Marija

engleski

SPE-HPLC/DAD determination of trimethoprim, oxytetracycline and enrofloxacin in water samples

In this paper high performance liquid chromatography with diode array UV detection (HPLC/DAD) after SPE sample pretreatment for simultaneous analysis of pharmaceuticals from three different classes: enrofloxacin, oxytetracycline and trimethoprim has been developed, optimised and validated. The chromatographic separation was developed on spiked wellspring water samples and cheeked on model wastewater samples of veterinary pharmaceuticals before and after RO/NF membrane treatment (feed and permeate streams) and on process wastewaters of industrial origin. Chromatographic separation was performed on Varian ProStar HPLC/DAD with C-18 column (Microsorb-MV 100 C18, 150x4.6 mm ; 5 µ ; ; ; ; m, Varian, USA). Detection and quantification was performed at 254 nm. The best separation was achieved with mobile phase 0.5 % formic acid and 1 % trifluoroacetic acid in 0.05 M ammonium acetate-methanol, 70+30, (v/v) after extraction procedure on polystyrenedivinylbenzene Varian Empore extraction disks. The extraction efficiency was checked by recovery experiments.

veterinary antibiotics ; trimethoprim ; oxytetracycline ; enrofloxacin ; water ; solid-phase extraction (SPE) ; high-performance liquid chromatography (HPLC) ; membrane treatment

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

89 (8-12)

2009.

809-819

objavljeno

0306-7319

1029-0397

10.1080/03067310902822896

Povezanost rada

Kemija, Temeljne tehničke znanosti

Poveznice
Indeksiranost