Active quenching circuit for single-photon detection with Geiger mode avalanche photodiodes (CROSBI ID 150451)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Stipčević, Mario Active quenching circuit for single-photon detection with Geiger mode avalanche photodiodes // Applied optics, 48 (2009), 9; 1705-1714. doi: 10.1364/AO.48.001705

Podaci o odgovornosti

Stipčević, Mario

engleski

Active quenching circuit for single-photon detection with Geiger mode avalanche photodiodes

In this paper a novel construction of an active quenching circuit intended for single-photon detection is presented, along with a few original methods for its evaluation. The circuit has been combined with a standard avalanche photodiode C30902S to form a single-photon detector. This detector has a dead time of 39 ns, maximum random counting frequency of 14 MHz, small afterpulsing probability, an estimated peak detection efficiency of over 20%, and a dark count rate of less than 100 Hz. This simple and robust active quenching circuit can be built from off-the-shelf electronic components and is presented with the detailed schematic diagram.

active quenching ; photon ; detector ; APD ; SPAD

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

48 (9)

2009.

1705-1714

objavljeno

0003-6935

2155-3165

10.1364/AO.48.001705

Povezanost rada

Fizika

Poveznice
Indeksiranost