Skowhegan type L100, MI calculation of inlet pipes (CROSBI ID 764363)
Druge vrste radova | stručna ekspertiza
Podaci o odgovornosti
Tevčić, Marina ; Hoppe, Jasna ; Orčić, Branislav
engleski
Skowhegan type L100, MI calculation of inlet pipes
The scope of MI is an investigation of fatigues of inlet pipes, which are parts for flow live steam from the control valve to the nozzle in the steam turbine casing. Analyzed several variants of turbine low cycle works “ start-operating-stop” with different times and temperature values to get a cause of pipe fatigues. The obtained results have been the base for redesign of inlet pipes
steam turbine; turbine casing; control valve; inlet pipe; nozzle; prescribed displacement; low cycle fatigue; ultimate strength