Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Isopotential points in reverse square-wave voltammetry (CROSBI ID 156809)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Zelić, Marina ; Lovrić, Milivoj Isopotential points in reverse square-wave voltammetry // Journal of electroanalytical chemistry (1992), 637 (2009), 1-2; 28-32. doi: 10.1016/j.jelechem.2009.09.026

Podaci o odgovornosti

Zelić, Marina ; Lovrić, Milivoj

engleski

Isopotential points in reverse square-wave voltammetry

Isopotential points in reverse square-wave voltammetry of irreversible electrode reactions are described for the first time. Experimental results (obtained with Eu3+ in perchlorate solutions) and model calculations indicate that such an intersection appears when the net signals, recorded at increasing step potential, are plotted together. As long as the transfer coefficient is equal to 0.5, the isopoint appears at the standard potential E0, irrespective of the kinetic parameter κ. Otherwise, it is shifted positively or negatively. The effect could be used for determination of the standard potential, recognition of symmetric/asymmetric processes and testing the quality of experimental data.

square-wave voltammetry ; reverse scan ; step potential ; isopoint ; europium ; standard potential

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

637 (1-2)

2009.

28-32

objavljeno

1572-6657

10.1016/j.jelechem.2009.09.026

Povezanost rada

Kemija

Poveznice
Indeksiranost