TEM-Cell with 75 W Impedance for EMC Measurements (CROSBI ID 474681)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Malarić, Krešimir ; Bartolić, Juraj
engleski
TEM-Cell with 75 W Impedance for EMC Measurements
This work gives an insight into the TEM-cells, their use and application. It deals with problems regarding characteristic impedance, higher mode, dimensions and usable test area. A TEM-cell designed at FER is presented here with initial results. This TEM-cell has characteristic impedance of 75 W and increased usable test area. It can be utilized for GSM as well as EMC measurements at 900 MHz due to the uniform TEM field on this frequency.
TEM-Cell
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
234-238-x.
1999.
objavljeno
Podaci o matičnoj publikaciji
Bill Gjertson
Seattle (WA): Institute of Electrical and Electronics Engineers (IEEE)
Podaci o skupu
1999 IEEE International Symposium on Electromagnetic Compatibility
predavanje
02.08.1999-06.08.1999
Seattle (WA), Sjedinjene Američke Države