Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography–diode array detection (CROSBI ID 159936)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Tomić, Tatjana ; Babić, Sandra ; Uzorinac Nasipak, Nada ; Fabulić Ruszkowski, Maja ; Škrobonja, Livijana ; Kaštelan-Macan, Marija Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography–diode array detection // Journal of Chromatography A, 1216 (2009), 18; 3819-3824. doi: 10.1016/j.chroma.2009.02.062

Podaci o odgovornosti

Tomić, Tatjana ; Babić, Sandra ; Uzorinac Nasipak, Nada ; Fabulić Ruszkowski, Maja ; Škrobonja, Livijana ; Kaštelan-Macan, Marija

engleski

Determination of alkenes in cracking products by normal-phase high-performance liquid chromatography–diode array detection

Alkene content determinations in fluid catalytic cracking (FCC) liquid products were performed by means of normal-phase high-performance liquid chromatography (NP-HPLC) with diode array detection (UV/DAD). Separation of alkenes from aromatic hydrocarbons was performed on amino-modified silica-gel column with n-heptane as mobile phase. The column has a little affinity to alkenes and saturated hydrocarbons and a pronounced affinity to aromatic compounds. The problem of alkenes and saturates co-elution on this column type was overcome with the detection system, UV/DAD, sensitive and selective to alkenes, while saturates are inactive in UV field. Total alkene content was determined as a sum of mono- and dialkene groups quantified by external standard method. Validation and verification of the developed method proved their applicability. The following criteria were used to validate the HPLC-DAD method: selectivity, linearity, precision, limits of detection and quantification. Alkene contents were quantified with the external standard method of wide calibration range, so both low and high alkene contents can be determined by the single calibration. Correlation coefficients were higher than 0.99. Precision was evaluated as repeatability and intermediary precision with relative standard deviations less than 5 %. Some structural investigation of alkene groups was performed to confirm the assumption. Proposed method was compared with certified NMR method. Six commercial motor gasoline samples were analyzed by these two methods. Obtained results indicate good agreement between alkene content determined by both methods. The developed method was applied to the determination of alkene content in liquid FCC products in the boiling range from 70 ºC to 190 ºC.

alkene ; FCC liquid products ; HPLC-DAD ; validation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

1216 (18)

2009.

3819-3824

objavljeno

0021-9673

1873-3778

10.1016/j.chroma.2009.02.062

Povezanost rada

Kemija

Poveznice
Indeksiranost