Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

OGLE 2008-BLG-290 : an accurate measurement of the limb darkening of a galactic bulge K Giant spatially resolved by microlensing (CROSBI ID 165586)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Fouqué, P. ; ... ; Dominis Prester, Dijana ; ... ; Seitz, S. OGLE 2008-BLG-290 : an accurate measurement of the limb darkening of a galactic bulge K Giant spatially resolved by microlensing // Astronomy & astrophysics, 518 (2010), A51-1-A51-12

Podaci o odgovornosti

Fouqué, P. ; ... ; Dominis Prester, Dijana ; ... ; Seitz, S.

engleski

OGLE 2008-BLG-290 : an accurate measurement of the limb darkening of a galactic bulge K Giant spatially resolved by microlensing

Not only is gravitational microlensing a successful tool for discovering distant exoplanets, but it also enables characterization of the lens and source stars involved in the lensing event. In high-magnification events, the lens caustic may cross over the source disk, which allows determination of the angular size of the source and measurement of its limb darkening. When such extended-source effects appear close to maximum magnification, the resulting light curve differs from the characteristic Paczyński point-source curve. The exact shape of the light curve close to the peak depends on the limb darkening of the source. Dense photometric coverage permits measurement of the respective limb-darkening coefficients. In the case of the microlensing event OGLE 2008-BLG-290, the K giant source star reached a peak magnification at about 100. Thirteen different telescopes have covered this event in eight different photometric bands. Subsequent light-curve analysis yielded measurements of linear limb-darkening coefficients of the source in six photometric bands. The best-measured coefficients lead to an estimate of the source effective temperature of about 4700+100-200 K. However, the photometric estimate from colour-magnitude diagrams favours a cooler temperature of 4200 ± 100 K. Because the limb-darkening measurements, at least in the CTIO/SMARTS2 V_s- and I_s-bands, are among the most accurate obtained, the above disagreement needs to be understood. A solution is proposed, which may apply to previous events where such a discrepancy also appeared.

gravitational lensing: micro; techniques: high angular; resolution; stars: atmospheres; stars: individual:; OGLE 2008-BLG-290

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

518

2010.

A51-1-A51-12

objavljeno

0004-6361

Povezanost rada

Fizika

Indeksiranost