Some problems related to surface temperature measurement of synchronous generator excitation winding in rotation (CROSBI ID 565972)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Hanić, Zlatko ; Vražić, Mario ; Stipetić, Stjepan
engleski
Some problems related to surface temperature measurement of synchronous generator excitation winding in rotation
This paper addresses some of the problems related to direct temperature measurement of synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the DS18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement on the surface of excitation winding conducted in the synchronous generator in the rotation.
surface temperature measurement; synchronous generator
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
T7-15-T7-20.
2010.
objavljeno
Podaci o matičnoj publikaciji
14th International Power Electronics and Motion Control Conference (EPE-PEMC 2010) : proceedings
Cvetkovski, Goga
Skopje: Faculty of Electrical Engineering and Information Technologies, Skopj
978-1-4244-7854-5
Podaci o skupu
International Power Electronics and Motion Control Conference (14 ; 2010)
poster
06.09.2010-08.09.2010
Ohrid, Sjeverna Makedonija