Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Environmental background dose measurements with TL and RPL dosimeters (CROSBI ID 567957)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Ranogajec-Komor, Maria ; Mócsy, Ildikó ; Csige Istvan ; Knežević, Željka Environmental background dose measurements with TL and RPL dosimeters // Proceedings of the Fifth International Workshop on Individual Monitoring of Ionizing Radiation / Yamamoto, Takayoshi (ur.). Ōarai: Chiyoda Technol Corporation (CTC), 2010. str. 193-202

Podaci o odgovornosti

Ranogajec-Komor, Maria ; Mócsy, Ildikó ; Csige Istvan ; Knežević, Željka

engleski

Environmental background dose measurements with TL and RPL dosimeters

Responding to the call of the Hungarian Academy of Sciences a research project was carried out for the development of a new method for preparing „radon map”. Within the frame of the Romanian-Hungarian-Croatian cooperation radon concentrations were estimated in buildings with various structures by a new mathematical model based on the measured radon concentration from the underlying soil close to the future or existing buildings. This presentation discusses the results of the inside and outdoor gamma dose measurements which were measured in addition to radon concentrations. Four different TL detector (TLD-100H, TLD-700, GR-200A, Al2O3:C) and RPL dosimeters were used for measuring the external gamma dose. 15 locations were selected in two settlements. Dosimeters were placed outside and inside the buildings. The mean values of the environmental gamma dose outside and inside on all locations were 0.24 mSv±8%. The following conclusions were drawn from the solid state dosimetry measurements: There was no systematic difference between the gamma dose values measured with TLDs or RPLDs. There was no significant difference (larger than the measurement uncertainty) between the environmental doses on the 15 outdoor locations. The standard deviation of 9% satisfies the requirements of the International Standard IEC:61066:2006. There was no difference between the outdoor and inside measured gamma doses on all locations indicating that the building materials do not influence the environmental gamma background dose. The measured gamma doses in this study (0.24-0.27 mSv) correspond to the natural environmental gamma radiation during the monitoring period (127 days).

Environmental monitoring; TLD; RPL

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

193-202.

2010.

objavljeno

Podaci o matičnoj publikaciji

Yamamoto, Takayoshi

Ōarai: Chiyoda Technol Corporation (CTC)

Podaci o skupu

Nepoznat skup

pozvano predavanje

29.02.1904-29.02.2096

Povezanost rada

Fizika, Kemija