Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Accelerated on-column lysine derivatization and cysteine methylation by imidazole reaction in a deuterated environment for enhanced product ion analysis (CROSBI ID 166968)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Cindrić, Mario ; Čepo, Tina ; Škrlin, Ana ; Vuletić, Marko ; Bindila, Laura Accelerated on-column lysine derivatization and cysteine methylation by imidazole reaction in a deuterated environment for enhanced product ion analysis // RCM. Rapid communications in mass spectrometry, 20 (2006), 4; 694-702. doi: 10.1002/rcm.2359

Podaci o odgovornosti

Cindrić, Mario ; Čepo, Tina ; Škrlin, Ana ; Vuletić, Marko ; Bindila, Laura

engleski

Accelerated on-column lysine derivatization and cysteine methylation by imidazole reaction in a deuterated environment for enhanced product ion analysis

The combination of separation techniques and mass spectrometry (MS) for peptide investigation allows superior sensitivity of detection and richer fragmentation data than available by direct MS analysis of a complex mixture. In this regard, liquid chromatography (LC) coupled to electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) MS have evolved as versatile analytical tools in proteomics. Very often, however, the product ion mass spectrum is either incomplete or overfilled with ions, thus making sequence analysis difficult. Here we report overall ion intensity improvement of C-terminal lysine-containing peptides from Lys-C digest by on-column derivatization of lysines with 2-methoxy-4, 5-dihydro-1H-imidazole. The method is simple, fast and exhibits 100% efficiency of the reaction. Additionally, post-source decay carried out on derivatized peptides gave rise almost exclusively to y-series ion formation, at 100% sequence coverage and high intensity. The novelty of the method resides in the side reaction of this derivatization process, namely the methylation of cysteines. This facilitates the estimation of the disulfide bridge position in a protein and the fragmentation of cysteine-containing peptide fragments. Additionally, by using this derivatization procedure, the loss of peptides, their degradation and/or oxidation, usually occurring in digest alkylation procedures, is greatly minimized. The new on-column derivatization protocol is designed to be carried out on C-18 Spin Tubes or Cleanup C18 Pipette Tips. We observed that use of buffered D2O solvent prevented unwanted oxidation and degradation reactions with respect to the stationary phase. This may be due to the fact that a deuteron is less polar than a proton, and thus the bonded silica stationary phase saturated with deuterons does not affect the reaction between epsilon-amino or cysteine thiol groups and 2-methoxy-4, 5-dihydro-1H- imidazole. Complete tagging of the peptides by on-column reaction could be obtained when using D2O, as compared to water-based reaction. Methylation of cysteine residues was enhanced when beta-mercaptoethanol was added in the reactant solution.

desorption/ionization mass-spectrometry ; protein identification ; liquid-chromatography ; containing peptides ; tryptic peptides ; guanidination ; dissociation ; homoarginine ; sensitivity

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

20 (4)

2006.

694-702

objavljeno

0951-4198

1097-0231

10.1002/rcm.2359

Povezanost rada

Biologija, Biotehnologija, Kemija

Poveznice
Indeksiranost