Stator damper winding and electromagnetic parameters of turbogenerators (CROSBI ID 572610)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Čelić, Kristina ; Dadić, Martin ; Vrzić, Velimir
engleski
Stator damper winding and electromagnetic parameters of turbogenerators
The increase of the load in specific active parts of modern turbogenerators causes higher local heating, higher magnetic leakage, increased forces of the electromagnetic origin and the increased acoustic noise level. Stator damper winding is an active cage-shaped constructive element positioned at the outer stator core diameter. Its influence has been investigated using numerical methods, since classical analytic model according to the two-axis theory and Park's equations is not applicable in this particular case.
Acoustic noise; Bars; Conducting materials; Electromagnetic forces; Joining processes; Machine windings; Packaging machines; Stator cores; Stator windings; Turbogenerators
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
416-421.
2010.
objavljeno
Podaci o matičnoj publikaciji
Institute of Electrical and Electronics Engineers (IEEE)
978-1-4244-5695-6
Podaci o skupu
IEEE International Conference on Industrial Technology ICIT 2010
predavanje
14.03.2010-17.03.2010
Valparaíso, Čile; Viña del Mar, Čile