Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Removal of antimicrobials using advanced wastewater treatment (CROSBI ID 171725)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Senta, Ivan ; Matošić, Marin ; Korajlija Jakopović, Helena ; Terzić, Senka ; Ćurko, Josip ; Mijatović, Ivan ; Ahel, Marijan Removal of antimicrobials using advanced wastewater treatment // Journal of hazardous materials, 192 (2011), 1; 319-328. doi: 10.1016/j.jhazmat.2011.05.021

Podaci o odgovornosti

Senta, Ivan ; Matošić, Marin ; Korajlija Jakopović, Helena ; Terzić, Senka ; Ćurko, Josip ; Mijatović, Ivan ; Ahel, Marijan

engleski

Removal of antimicrobials using advanced wastewater treatment

Removal of numerous classes of pharmaceuticals from the municipal and industrial wastewater, using conventional wastewater treatment, is incomplete and several studies suggested that improvement of this situation would require the application of advanced treatment techniques. This is particularly important for the treatment of industrial effluents, released from pharmaceutical industries, which can contain rather high concentrations of antimicrobials. The aim of this work was to evaluate membrane bioreactors (MBRs), nanofiltration, reverse osmosis and ozonation, as well as their combinations, for the removal of antimicrobials from a synthetic wastewater which simulated highly contaminated industrial effluents. The study was performed using a mixture of four important classes of antimicrobials, including sulfonamides (SA), fluoroquinolones (FQ), macrolides (MAC) and trimethoprim (TMP). Performance of two different types of MBRs, Kubota and Zenon, was evaluated under different regimes regarding hydraulic retention time, total organic load and total nitrogen load. It was shown that elimination of SA in MBR treatment was very efficient, while the elimination of MAC, FQ, and TMP was incomplete. A mass balance of these contaminants in MBR suggested that microbial transformation represented the main mechanism, while only a small percentage was eliminated from the aqueous phase by adsorption onto sludge particles. Nanofiltration and reverse osmosis achieved high elimination rates however produced highly contaminated concentrate. High removal was achieved using ozonation, but further research is needed to characterize formed ozonation products.

pharmaceuticals ; membrane bioreactor ; nanofiltration ; reverse osmosis ; ozonation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

192 (1)

2011.

319-328

objavljeno

0304-3894

1873-3336

10.1016/j.jhazmat.2011.05.021

Povezanost rada

Geologija, Biotehnologija

Poveznice
Indeksiranost