Measuring Power MOSFET Virtual Junction Temperature in Operating Conditions (CROSBI ID 574488)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Šunde, Viktor ; Benčić, Zvonko ; Jakopović, Željko Measuring Power MOSFET Virtual Junction Temperature in Operating Conditions // Proceedings 9th EDPE / Ban, Drago ; Benčić, Zvonko (ur.). Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 1996. str. 81-85

Podaci o odgovornosti

Šunde, Viktor ; Benčić, Zvonko ; Jakopović, Željko

engleski

Measuring Power MOSFET Virtual Junction Temperature in Operating Conditions

Present methods for measuring power MOSFET virtual junction temperature do not alow temperature to be measured while its operates within a certain circuit. A method is presented which permits the measurement of power MOSFETs temperature inside the chopper. It is an electrical method which takes the on-state voltage of a power MOSFETs integrated reverse diode as a temperature-dependent parameter. The concept of this method was tested by simulating it on a Micro-Cap II program. Measuring equipment is bein developed and promising results have been obtained.

power MOSFET; virtual junction temperature; operating conditions

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

81-85.

1996.

objavljeno

Podaci o matičnoj publikaciji

Ban, Drago ; Benčić, Zvonko

Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA)

953-6037-19-x

Podaci o skupu

The 9^th International Conference Electrical Drives and Power Electronics

predavanje

09.10.1996-11.10.1996

Dubrovnik, Hrvatska

Povezanost rada