Monitoring of Rotor Bar Faults in Induction Generators with Full-Size Inverter (CROSBI ID 576814)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Stojičić, Goran ; Samonig, Matthias ; Nussbaumer, Peter ; Joksimović, Gojko ; Vašak, Mario ; Perić, Nedjeljko ; Wolbank, Thomas
engleski
Monitoring of Rotor Bar Faults in Induction Generators with Full-Size Inverter
Monitoring of generators is an essential part when operating a plant in remote areas. Nowadays demands on system reliability are very high and thus maintenance at regular intervals is necessary. Standard fault detection methods are usually based on several additional sensors. Such monitoring systems increase system costs and afford an additional source of fault. To avoid this disadvantage an alternative technique based only on the usage of sensors already available in the power inverter will be shown. The method is based on machine’s response due to voltage pulses generated by inverter switching. Measurement of the current response and subsequent signal processing leads to very detailed information about the machine state. Identification and separation of machine asymmetries obtained from two subsequent Fast Fourier Transformations offer a high sensitive fault indicator. The generation of the excitation pulses, current sampling and the signal processing chain as well will be described. Measurements for several levels of rotor bar fault severity are presented and the fault detection sensitivity and efficiency is proven.
condition monitoring; fault diagnosis; induction machines; rotor broken bar faults; transient excitation
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
8 pages-x.
2011.
objavljeno
Podaci o matičnoj publikaciji
9789075815153
Podaci o skupu
EPE'11 ECCE Europe Power Electronics and Adjustable Speed Drives: Towards the 20-20-20 Target
predavanje
30.08.2011-01.09.2011
Birmingham, Ujedinjeno Kraljevstvo