Energy Savings by Flux Optimisation in AC Motors with Frequency Drives (CROSBI ID 477511)
Prilog sa skupa u zborniku | stručni rad | domaća recenzija
Podaci o odgovornosti
Granoša, Željko ; Lisica, Krešimir
engleski
Energy Savings by Flux Optimisation in AC Motors with Frequency Drives
The paper emphasises the energy saving possibilities of AC motors controlled by frequency drives with the implementation of a Direct Torque Control algorithm. Energy savings should be achieved by flux optimisation in the AC motor, based on a motor driven working machine load. Electrical energy consumption was measured on different types of machines, driven during the normal production in a multipurpose chemical synthesis plant.
energy saving; frequency drives; AC motor; Direct Torque Control
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
208-213-x.
2000.
objavljeno
Podaci o matičnoj publikaciji
Proceedings 11th EDPE - International Conference Electrical Drives and Power Electronics
---
Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA)
Podaci o skupu
Electrical Drives and Power Electronics
predavanje
09.09.2000-11.09.2000
Hrvatska