Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Modeling of Saturated Synchronous Generator Based on Steady-State Operating Data (CROSBI ID 185044)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Despalatović, Marin ; Jadrić, Martin ; Terzić, Božo Modeling of Saturated Synchronous Generator Based on Steady-State Operating Data // IEEE transactions on industry applications, 48 (2012), 1; 62-69. doi: 10.1109/TIA.2011.2175429

Podaci o odgovornosti

Despalatović, Marin ; Jadrić, Martin ; Terzić, Božo

engleski

Modeling of Saturated Synchronous Generator Based on Steady-State Operating Data

This paper deals with modeling of the saturated salient-pole synchronous machines using analytical saturation model obtained based on measurements of steady-state variables. Two different saturation models are considered in order to investigate impact of the reciprocity property of the mutual inductance between d- and q-axis on transients of the saturated machine. It is shown that the simpler saturation model, which is obtained by neglecting the reciprocity property condition, may be used to model saturation in both steady-state and transient conditions. The developed model of the saturated machine is validated with measurements performed on the 34-MVA hydroturbine generator.

mMain flux saturation; modeling; monitoring; parameter estimation; simulation; synchronous machines

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

48 (1)

2012.

62-69

objavljeno

0093-9994

10.1109/TIA.2011.2175429

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost