Reliability of glulam beams exposed to fire (CROSBI ID 589317)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Stepinac, Mislav ; Rajčić, Vlatka ; Androić, Boris ; Čizmar, Dean
engleski
Reliability of glulam beams exposed to fire
This paper presents reliability analysis of a glulam load-bearing beam in a fire. Global fire safety concept of timber structure analysis is presented according to the recommendations from Eurocodes. Special attention was given to natural fire design with two different methods of parametric exposure which are given in Eurocode 1995-1-2. Differences in load-bearing capacity from Eurocode 1995-1-1 and 1995-1-2 are. The limit-state functions for maximum bending stress of glulam beam in fire conditions are formed. The charring rate of wooden beam is calculated by a model that includes explicitly the principal sources of uncertainties and variability. Reliability indexes are obtained from the limit state of the beam exposed to 30 min fire for the beams which spans were varied from 4 to 12 meters. Conclusions are given about structures with reliability class RC3 for which design according only to Eurocode 1995-1-2 is not sufficient.
glulam beam; reliability; fire; Eurocode; bending; the limit state function
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
534-539.
2012.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of World Conference on Timber Engineering (WCTE)
Quenneville, Pierre
Auckland:
Podaci o skupu
World Conference on Timber Engineering
poster
15.07.2012-19.07.2012
Auckland, Novi Zeland