Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Influence of adsorption of pharmaceuticals onto RO/NF membranes on their removal from water (CROSBI ID 187531)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Dolar, Davor ; Košutić, Krešimir ; Ašperger, Danijela Influence of adsorption of pharmaceuticals onto RO/NF membranes on their removal from water // Water, air and soil pollution, 224 (2013), 1; 1377, 13. doi: 10.1007/s11270-012-1377-0

Podaci o odgovornosti

Dolar, Davor ; Košutić, Krešimir ; Ašperger, Danijela

engleski

Influence of adsorption of pharmaceuticals onto RO/NF membranes on their removal from water

Adsorption together with size exclusion and charge attraction/repulsion has to be taken into account when considering removal of pharmaceuticals as emerging contaminants from water by reverse osmosis (RO) and nanofiltration (NF) membranes. Glucocorticosteroids (hydrocortisone (HYDRO), dexamethasone (DEXA)), anesthetics (procaine (PROCA), lidocaine (LIDO)) with relatively weak hydrophobicities (1 < log KO/W < 3) and membranes (XLE, LFC–1, CPA3, SWC1, NF90 and NF270) have been investigated in this study. Adsorption was studied by measuring the concentration of compounds in feed and permeate and by monitoring changes in membrane flux in the batch mode operation during 24 h. A decrease in the feed concentrations for HYDRO and DEXA (log KO/W < 2) was observed. The loss of these compounds in feed was associated with irreversible adsorption onto an NF270 and a CPA3 membrane. Therefore, when considering removal of pharmaceuticals with lower hydrophobicity, adsorption has to be particularly taken into account for membranes with bigger pores in the selective layer. Also a high dipole moment and low water solubility affected adsorption on the membranes. For smaller and slightly more hydrophobic pharmaceuticals (log KO/W > 2), an increase in the feed concentration was obtained. Firstly, these compounds instantly adsorbed to the membrane. Secondly, the compounds diffused through the polymer matrix and desorbed to the permeate side after equilibrium had been reached.

adsorption; hydrocortisone; dexamethasone; procaine; lidocaine; RO/NF

Djelomično sufinancirano po bilateralnom projektu HR (Ašperger) - SLO (Kosjek): Determination of toxicity and physico-chemical properties of pharmaceuticals.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

224 (1)

2013.

1377

13

objavljeno

0049-6979

1573-2932

10.1007/s11270-012-1377-0

Povezanost rada

Kemija, Kemijsko inženjerstvo, Temeljne tehničke znanosti, Interdisciplinarne tehničke znanosti

Poveznice
Indeksiranost