Identification of the contents and shelf-life of field kits for the detection of organophosphorus compounds in the air (CROSBI ID 462964)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Simeon-Rudolf, Vera ; Škrinjarić-Špoljar, Mira ; Reiner, Elsa ; Orehovec, Zvonko ; Jukić, Ivan ; Bokan, Slavko ; Smoljan, Branko Identification of the contents and shelf-life of field kits for the detection of organophosphorus compounds in the air // Technical Program, CB Medical Treatment Symposium: An Exploration of Present Capabilities and Future Requirements for Chemical and Biological Medical Treatment, Abstracts of Platform and Poster Presentations, Spiez, Švicarska, 1966 / Price, Barbara (ur.). Spiez: NC-Laboratory Spiez, Švicarska, 1996. str. 14-15-x

Podaci o odgovornosti

Simeon-Rudolf, Vera ; Škrinjarić-Špoljar, Mira ; Reiner, Elsa ; Orehovec, Zvonko ; Jukić, Ivan ; Bokan, Slavko ; Smoljan, Branko

engleski

Identification of the contents and shelf-life of field kits for the detection of organophosphorus compounds in the air

Eleven sets of glass indicator tubes for detection of organophosphorus compounds in the air were analyzed for their content and tested on their shelf-life. Sets of tubes were integral parts of army field kits found on the territory of Croatia during the 1991/1992 war. The sets were denoted with serial numbers and dates of validity expiration (from 1974 to 1992) but without statement on the content and manufacturer. Glass tubes were identified to contain a cholinesterase preparation, a non-thiocholine substrate of cholinesterase and a pH-sensitive indicator. Their functioning was tested by use of dimethyl dichlorovinyl phosphate (DDVP). All tested sets were found to be valid for detection which indicated a long shelf-life of the field kits.

cholinesterase preparation; cholinesterase inhibitors; validity of OP detection kit

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

14-15-x.

1996.

objavljeno

Podaci o matičnoj publikaciji

Technical Program, CB Medical Treatment Symposium: An Exploration of Present Capabilities and Future Requirements for Chemical and Biological Medical Treatment, Abstracts of Platform and Poster Presentations, Spiez, Švicarska, 1966

Price, Barbara

Spiez: NC-Laboratory Spiez, Švicarska

Podaci o skupu

The Second Chemical and Biological Medical Treatment Symposium

poster

07.07.1996-12.07.1996

Spiez, Švicarska

Povezanost rada

Kliničke medicinske znanosti