Simplified Out-of-plane Resistance Verification for Slender Clay Masonry Infills in RC Frames (CROSBI ID 598123)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Morandi, Paolo ; Hak, Sanja ; Magenes, Guido Simplified Out-of-plane Resistance Verification for Slender Clay Masonry Infills in RC Frames // Atti del XV convegno ANIDIS 2013 / ANIDIS (ur.). Padova, 2013

Podaci o odgovornosti

Morandi, Paolo ; Hak, Sanja ; Magenes, Guido

engleski

Simplified Out-of-plane Resistance Verification for Slender Clay Masonry Infills in RC Frames

Field observations from recent earthquakes in Italy have shown numerous examples of unsatisfactory out-of-plane performance of masonry infills and façade veneers. Extensive damage in some cases has occurred also in recently constructed buildings, indicating the need for improved detailing and a more effective design procedure. The design recommendations related to the verification of the out-of-plane stability in currently adopted code regulations are rather general, providing a simplified approach for the approximation of seismic action effects. However, no recommendations related to the evaluation of the infill resistance are given. In principle, resistance models based on arching action can be used, but they may be considered appropriate only for undamaged infills built in contact with the frame. Due to the directionally combined infill degradation in the case of horizontal loading induced by earthquakes, the out-of-plane strength verification of infills damaged due to excitations in the in-plane direction appears to be governing the design. In this work, the application of the current design procedure for non-structural masonry is studied, and the relation between in-plane and out-of-plane damage is examined, starting from existing experimental results. Consequently, proposals for a simplified design approach are provided, accounting for expected levels of in-plane damage in the out-of-plane safety verification.

Masonry infill; Out-of-plane resistance; In-plane and out-of-plane damage; RC frame design

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2013.

objavljeno

Podaci o matičnoj publikaciji

Atti del XV convegno ANIDIS 2013

ANIDIS

Padova:

Podaci o skupu

ANIDIS 2013 - XV Convegno di Ingegneria Sismica

predavanje

30.06.2013-04.07.2013

Padova, Italija

Povezanost rada

Građevinarstvo