Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection (CROSBI ID 196066)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Mutavdžić Pavlović, Dragana ; Ašperger, Danijela ; Tolić, Dijana ; Babić, Sandra Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection // Journal of separation science, 36 (2013), 18; 3042-3049. doi: 10.1002/jssc.201300486

Podaci o odgovornosti

Mutavdžić Pavlović, Dragana ; Ašperger, Danijela ; Tolić, Dijana ; Babić, Sandra

engleski

Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection

This paper describes the development, optimization, and validation of a method for the determination of five pharmaceuticals from different therapeutic classes (antibiotics, anthelmintics, glucocorticoides) in water samples. Water samples were prepared using SPE and extracts were analyzed byHPLCwith diode-array detection. The efficiency of 11 different SPE cartridges to extract the investigated compounds from water was tested in preliminary experiments. Then, the pH of the water sample, elution solvent, and sorbent mass were optimized. Except for optimization of the SPE procedure, selection of the optimal HPLC column with different stationary phases from different manufacturers has been performed. The developed method was validated using spring water samples spiked with appropriate concentrations of pharmaceuticals. Good linearity was obtained in the range of 2.4–200g/L, depending on the pharmaceutical with the correlation coefficients >0.9930 in all cases, except for ciprofloxacin (0.9866). Also, the method has revealed that low LODs (0.7–3.9 g/L), good precision (intra- and interday) with RSD below 17% and recoveries above 98% for all pharmaceuticals. The method has been successfully applied to the analysis of production wastewater samples from the pharmaceutical industry.

HPLC / optimization ; pharmaceuticals ; production wastewater ; SPE

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

36 (18)

2013.

3042-3049

objavljeno

1615-9306

1615-9314

10.1002/jssc.201300486

Povezanost rada

Kemija

Poveznice
Indeksiranost