Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Spectroscopic and catalytic probe characterization of oxygen and hydrogen plasmas (CROSBI ID 600876)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Kregar, Zlatko ; Bišćan, Marijan ; Zaplotnik, Rok ; Milošević, Slobodan Spectroscopic and catalytic probe characterization of oxygen and hydrogen plasmas // Programme and Book of Abstracts, 20th International Scientific meeting on Vacuum science and techniques / Mozetič, Miran ; Vesel, Alenka (ur.). Ljubljana: Slovenian Society for Vacuum Technique (DVTS), 2013. str. 48-48

Podaci o odgovornosti

Kregar, Zlatko ; Bišćan, Marijan ; Zaplotnik, Rok ; Milošević, Slobodan

engleski

Spectroscopic and catalytic probe characterization of oxygen and hydrogen plasmas

Inductively coupled plasma modification of surface is a well-established technique used in a wide variety of applications. Reactive and fast interaction between the plasma and sample shows the need for real-time plasma diagnostics. Optical emission spectroscopy and actinometry combined with the measurement of oxygen atom concentrations by the catalytic probe offer a relatively simple and efficient solution for that need. The combination of these methods was used for characterization of low pressure inductively coupled oxygen and hydrogen plasma in an afterglow chamber and the discharge tube. Plasma was created in a linear borosilicate glass tube by a 6 turn coil with an EM field oscillating at 13.56 MHz at the distance of 30 cm from the center of the afterglow chamber. Various plasma conditions were used: oxygen and hydrogen gas pressure (10-70 Pa), discharge powers (up to 260 W of applied power) and different plasma modes (E and H modes) . The spectrometer Avantes 3648 is calibrated for the spectral response and used for actinometry measurements. Ni-plated catalytic probe was used for measuring neutral oxygen atom concentrations, while Au probe was used for neutral hydrogen atoms. Oxygen atom concentrations were measured (by the catalytic probe and actinometry) to be in the range from 5•1018 m-3 (lowest pressure, furthest position) to 2•1021 m-3 (70 Pa, near the coil). Significant concentrations of oxygen atoms were measured even in the “dark” parts of the afterglow chamber.

optical emission spectroscopy; inductively coupled plasma; catalytic probes; actinometry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

48-48.

2013.

objavljeno

Podaci o matičnoj publikaciji

Programme and Book of Abstracts, 20th International Scientific meeting on Vacuum science and techniques

Mozetič, Miran ; Vesel, Alenka

Ljubljana: Slovenian Society for Vacuum Technique (DVTS)

978-961-92989-5-4

Podaci o skupu

20th International Scientific meeting on vacuum science and technique

poster

09.05.2013-10.05.2013

Jeruzalem, Slovenija

Povezanost rada

Fizika