Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments (CROSBI ID 197649)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Cobelo-Garcia, Antonio ; Santos-Echeandia, Juan ; Lopez-Sanchez, Daniel ; Almecija, Clara ; Omanović, Dario ; Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments // Analytical chemistry, 86 (2014), 5; 2308-2313. doi: 10.1021/ac403558y

Podaci o odgovornosti

Cobelo-Garcia, Antonio ; Santos-Echeandia, Juan ; Lopez-Sanchez, Daniel ; Almecija, Clara ; Omanović, Dario ;

engleski

Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments

The determination of trace elements using stripping voltammetry may be seriously affected by the presence of intensive matrix background or interfering peaks, leading to poorer detection limits and/or inaccurate quantitative results. In this work, we have tested the use of signal transformation (e.g., second derivative) in the analysis of platinum in seawater and sediment digests by means of catalytic adsorptive stripping voltammetry. In natural waters, the limit of detection of Pt is affected by a broad background wave due to the formazone complex used in the sample matrix for its determination, while in sediment digests, the Pt peak may be interfered with due to the presence of elevated concentrations of Zn, affecting the accuracy of the determination. Results applying second derivative signal transformation revealed a significant improvement (2–3-fold) of the detection limit in water due to the minimization of background effects, therefore allowing shorter accumulation times and faster determinations. In the presence of interfering peaks, the inaccuracy resulting from erroneous baseline selection in the original signal is eliminated when the second derivative is used. Signal processing should be considered as a useful tool for other voltammetric methodologies where more accurate or faster determinations are needed.

platinum; signal processing; voltammetry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

86 (5)

2014.

2308-2313

objavljeno

0003-2700

10.1021/ac403558y

Povezanost rada

Geologija, Kemija

Poveznice
Indeksiranost