Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Possibilities of electricity generation in the Republic of Croatia from medium-temperature geothermal sources (CROSBI ID 199687)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Guzović, Zvonimir ; Majcen, Boris ; Cvetković, Svetislav Possibilities of electricity generation in the Republic of Croatia from medium-temperature geothermal sources // Applied energy, 98 (2012), 404-414. doi: 10.1016/j.apenergy.2012.03.064

Podaci o odgovornosti

Guzović, Zvonimir ; Majcen, Boris ; Cvetković, Svetislav

engleski

Possibilities of electricity generation in the Republic of Croatia from medium-temperature geothermal sources

In the Republic of Croatia, there are several sources of medium-temperature geothermal water in the range of 90–140 degrees Celsius, with which it is possible to produce electricity in binary plants, either with the Organic Rankine Cycle (ORC) or with the Kalina cycle. In the literature, the Kalina cycle is viewed as more thermodynamically favourable than the ORC ; i.e., the Kalina cycle has a higher thermal efficiency and produces more power. However, the Croatian experience with a medium-temperature geothermal source with the relatively high temperature of geothermal water (Velika Ciglena, 175 degrees Celsius) is that the ORC is thermodynamically better than the Kalina cycle. In this paper, a comparison between the ORC and the Kalina cycle is performed based on energy analysis results for a medium-temperature geothermal source with a relatively lower temperature (Lunjkovec–Kutnjak, 140 degrees Celsius). Additionally, in this case the ORC has better thermal efficiency (First Law efficiency) – 13.5% vs. 12.8% – and accordingly higher net power – 2225.5 kW vs. 2101.4 kW. This difference is explained by the relatively high average annual temperature of the cooling air in the condenser (15 degrees Celsius), which has a more unfavourable influence on the condensing pressure in the Kalina cycle than in the ORC (6.35 bar vs. 0.68 bar).

geothermal energy; geothermal power plant; Organic Rankine Cycle (ORC); Kalina cycle; Lunjkovec-Kutnjak-Croatia

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

98

2012.

404-414

objavljeno

0306-2619

10.1016/j.apenergy.2012.03.064

Povezanost rada

Strojarstvo

Poveznice
Indeksiranost