Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector (CROSBI ID 200390)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Forneris, Jacopo ; Grilj, Veljko ; Jakšić, Milko ; Lo Giudice, Alessandro ; Olivero, Paolo ; Picollo, Federico ; Skukan, Natko ; Verona, Claudio ; Verona-Rinati, Gianluca ; Vittone, Ettore Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector // Europhysics letters, 104 (2013), 28005-1-28005-6. doi: 10.1209/0295-5075/104/28005

Podaci o odgovornosti

Forneris, Jacopo ; Grilj, Veljko ; Jakšić, Milko ; Lo Giudice, Alessandro ; Olivero, Paolo ; Picollo, Federico ; Skukan, Natko ; Verona, Claudio ; Verona-Rinati, Gianluca ; Vittone, Ettore

engleski

Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector

In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers' transport properties of the device. The resulting charge-sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of the device to ionizing radiation. This latter effect has recently attracted attention in commonly used detector materials, but different interpretations have been suggested, depending on the material, the geometry of the device and the nature of the ionizing radiation. In this letter, we report on the investigation in the formation of anomalous polarity pulses in a multi-electrode diamond detector with buried graphitic electrodes. In particular, we propose a purely electrostatic model based on the Shockley-Ramo-Gunn theory, providing a satisfactory description of anomalous pulses observed in charge collection efficiency maps measured by means of Ion Beam Induced Charge (IBIC) microscopy, and suitable for a general application in multi-electrode devices and detectors.

solid-state detectors; diamond

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

104

2013.

28005-1-28005-6

objavljeno

0295-5075

10.1209/0295-5075/104/28005

Povezanost rada

Fizika

Poveznice