Internal bremsstrahlung in 2p-electron capture decay of ^(179)Ta (CROSBI ID 480572)
Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija
Podaci o odgovornosti
Vuković, Branko ; Ilakovac, Ksenofont
engleski
Internal bremsstrahlung in 2p-electron capture decay of ^(179)Ta
(Part of abstract) A weak source of radioactive ^(179)Ta and two germanium detectors were used in the measurements. Data above the Kalpha_1 and Kalpha_2 peaks in coincidence with the L X-rays of hafnium show the spectra of bremsstrahlung photons due to radiative 2-p electron capture. The spectra were analysed using the nonrelativistic theory of radiative electron capture which was modified to take into account the real energies at resonance and widths of the resonance peaks.
2p-electron capture; ^(179)Ta; internal bremsstrahlung; resonance effect
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
109-109-x.
1996.
objavljeno
Podaci o matičnoj publikaciji
17th International Conference X-Ray and Inner-Shell Processes
Sonntag, B. ; Zimmerer, G. ; Laasch, W.
Hamburg: HASYLAB-DESY
Podaci o skupu
17th International Conference X-Ray and Inner-Shell Processes
poster
09.09.1996-13.09.1996
Hamburg, Njemačka