Computer-Aided Evaluation of Radiologist’s Reproducibility and Subjectivity in Mammographic Density Assessment (CROSBI ID 204308)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Tomaš, Ilijan ; Kotoromanović, Zdenka ; Belaj, Nenad ; Margaretić, Damir ; Ivezić, Zdravko ; Katić, Miroslav ; Zibar, Lada ; Faj, Dario ; Štimac, Damir ; Matić, Mate Computer-Aided Evaluation of Radiologist’s Reproducibility and Subjectivity in Mammographic Density Assessment // Collegium antropologicum, 37 (2013), 4; 1121-1126

Podaci o odgovornosti

Tomaš, Ilijan ; Kotoromanović, Zdenka ; Belaj, Nenad ; Margaretić, Damir ; Ivezić, Zdravko ; Katić, Miroslav ; Zibar, Lada ; Faj, Dario ; Štimac, Damir ; Matić, Mate

engleski

Computer-Aided Evaluation of Radiologist’s Reproducibility and Subjectivity in Mammographic Density Assessment

Mammographic density is an independent risk of breast cancer. This study has evaluated the radiologists’ reproducibility and subjectivity in breast density estimation and in order to decrease the radiologists’ subjective errors the computer software was developed. The very good reproducibility existed in the strong correlation with the first and the second mammogram assessment after three month period for each radiologist (correlation coefficient 0.73–1, p<0.001). The strong correlation was present in the case of all 5 radiologists when compared among themselves and compared with software aided MDEST-Mammographic Density Estimation (correlation coefficient 0.651–0.777, p<0.001). Detected differences in glandular tissue percentage determination occurred in the case of two experienced radiologists, out of 5 (one radiologist with more than 5 year experience and one with more than 10 year experience, p<0.01), but in the case of breast type determination (American College of Radiology-ACR I-IV), the detected difference occurred in one radiologist with the least experience (less than 5 years, p<0.001). It can be concluded that the estimation of glandular tissue percentage in breast density is rather subjective method, especially if it is expressed with absolute percentage, but the determination of type of breast (ARCI-IV) depends on the radiologist’s experience. This study showed that software aided determination of glandular tissue percentage and breast type can be of a great benefit in the case of less experienced radiologists.

mammography; breast density; subjectivity; software