Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Lešić, Vinko ; Vašak, Mario ; Perić, Nedjeljko ; Jakopović, Željko ; Joksimović, Gojko ; Wolbank, Thomas M. Influence of Wind Turbine Generator Fault-tolerant Control on Power Production Quality // Proceedings of the 7th IET international conference on Power Electronics, Machines and Drives, PEMD. 2014. str. 1-6

Podaci o odgovornosti

Lešić, Vinko ; Vašak, Mario ; Perić, Nedjeljko ; Jakopović, Željko ; Joksimović, Gojko ; Wolbank, Thomas M.

engleski

Influence of Wind Turbine Generator Fault-tolerant Control on Power Production Quality

Renewable energy sources bring to fore the significance of power electronics and corresponding control. The topic of wind turbine fault-tolerant control has emerged as a promising line of research for improving their market competence. The paper presents summarized control of wind turbine converter with a fault-tolerant control extension for generator electromechanical faults, based on a proper modulation of the stator magnetic flux. The modulation also introduces hard periodic oscillations in the stator currents and generator output power. Simulation results obtained with a Matlab-Simplorer co-simulation and detailed power converter model show that DC-link capacitor and corresponding control algorithm act like an energy buffer that suppress the influence of generator stator oscillations on currents passed to the grid and maintain the high quality of power production. Following from the results, the generator and grid side controls are justified to be considered as two independent problems.

Wind Energy Quality; Field-oriented Control; Voltage-oriented Control; Fault-tolerant Control; Matlab- Simplorer Co-simulation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-6.

2014.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

7th IET international conference on Power Electronics, Machines and Drives, PEMD

predavanje

08.04.2014-10.04.2014

Manchester, Ujedinjeno Kraljevstvo

Povezanost rada

Temeljne tehničke znanosti