Comparison of two commercial enzyme-linked immunosorbent assays for cerebrospinal fluid measurement of amyloid β1–42 and total tau (CROSBI ID 206040)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Babić, Mirjana ; Vogrinc, Željka ; Diana, Andrea ; Klepac, Nataša ; Borovečki, Fran ; Hof, Patrick R. ; Šimić, Goran Comparison of two commercial enzyme-linked immunosorbent assays for cerebrospinal fluid measurement of amyloid β1–42 and total tau // Translational Neuroscience, 4 (2013), 2; 234-240. doi: 10.2478/s13380-013-0123-4

Podaci o odgovornosti

Babić, Mirjana ; Vogrinc, Željka ; Diana, Andrea ; Klepac, Nataša ; Borovečki, Fran ; Hof, Patrick R. ; Šimić, Goran

engleski

Comparison of two commercial enzyme-linked immunosorbent assays for cerebrospinal fluid measurement of amyloid β1–42 and total tau

Amyloid β1–42 (Aβ1–42), total tau (t-tau), and phosphorylated tau (p-tau) are the main cerebrospinal fluid (CSF) biomarkers for early diagnosis of Alzheimer’s disease (AD). Detection of AD is critically important in view of the growing number of potential new drugs that may influence the course of the disease in its early phases. However, cut-off levels for these CSF biomarkers have not yet been established. Variability in absolute concentrations of AD biomarkers is high among studies and significant differences were noticed even within the same datasets. Variability in biomarkers levels in these assays may be due to many aspects of operating procedures. Standardization of pre- analytical and analytical procedures in collection, treatment, and storage of CSF samples is crucial because differences in sample handling can drastically influence results. Multicenter studies showed that usage of ELISA kits from different manufacturers also affects outcome. So far only very few studies tested the efficiency of ELISA kits produced by different vendors. In this study, the performance of Innogenetics (Gent, Belgium) and Invitrogen (Camarillo, CA, USA) ELISA kits for t-tau and Aβ1–42 was tested. Passing- Bablok analysis showed significant differences between Invitrogen and Innogenetics ELISA methods, making it impossible to use them interchangeably.

Alzheimer’s disease ; biomarkers ; cerebrospinal fluid

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

4 (2)

2013.

234-240

objavljeno

2081-3856

2081-6936

10.2478/s13380-013-0123-4

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost