Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Pregled osobnih doza djelatnika KBC "Sestre milosrdnice" u desetogodišnjem razdoblju (CROSBI ID 610810)

Prilog sa skupa u zborniku | stručni rad | domaća recenzija

Mrčela, Iva ; Bokulić, Tomislav ; Budanec, Mirjana , Surić Mihić, Marija ; Gregov, Marin ; Mlinarić, Mihaela ; Kusić, Zvonko Pregled osobnih doza djelatnika KBC "Sestre milosrdnice" u desetogodišnjem razdoblju // Proceedings of the ninth symposium of the Croatian radiation Protection Association / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 334-339

Podaci o odgovornosti

Mrčela, Iva ; Bokulić, Tomislav ; Budanec, Mirjana , Surić Mihić, Marija ; Gregov, Marin ; Mlinarić, Mihaela ; Kusić, Zvonko

hrvatski

Pregled osobnih doza djelatnika KBC "Sestre milosrdnice" u desetogodišnjem razdoblju

Personal dose monitoring in UHC “Sestre milosrdnice” is regulary performed for about 300 exposed workers involved in a variety of tasks with different sources of ionizing radiation. Exposed workers are required to wear personal dosimeters which are read on monthly basis and dose records are kept in the hospital. In this paper an overview of personal dosimetry data from year 2003 till 2013 is presented. Film dosimeters were used for personal dosimetry untill 2010th when the thermoluminescent (TL) dosimetry was introduced. Dosimeters are calibrated to measure personal dose equivalent Hp(10). Received doses are analyzed for workers in the field of nuclear medicine, radiotherapy (external beam and brachytherapy), general diagnostic radiology and interventional radiology. Analysis of received doses in the whole period resulted with an average individual dose in nuclear medicine of 0, 6 mSv/y, which decreased to 0, 21 mSv/y in the last three years, caused by more precise dosimetric methods with TL dosimetry and improved conditions of radiation protection. In the same three year period, in interventional radiology doses were 0, 32 mSv/y, compared to 0, 29 mSv/y obtained for a previous seven years. This was expected due to the escalation in a number of interventions and new installed equipment. There was no such difference in diagnostic radiology doses, showing that film dosimetry is suitable for x ray energies. Analysis of all the readings showed a significant influence of measurement procedures on personal dosimeter dose and also the importance of continuous monitoring of the dose records in order to improve the conditions of radiation protection and achieving the ALARA goal.

osobna dozimetrija

nije evidentirano

engleski

Personal dosimetry in UHC "Sestre milosrdnice": a 10- years review

nije evidentirano

personal dosimetry

nije evidentirano

Podaci o prilogu

334-339.

2013.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the ninth symposium of the Croatian radiation Protection Association

Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines

Zagreb: Hrvatsko društvo za zaštitu od zračenja

978-953-96133-8-7

Podaci o skupu

9. SIMPOZIJ HRVATSKOG DRUŠTVA ZA ZAŠTITU OD ZRAČENJA

predavanje

10.04.2013-12.04.2013

Krk, Hrvatska

Povezanost rada

Fizika

Poveznice