Study of the inter-strip gap effects on the response of Double Sided Silicon Strip Detectors using proton micro-beams (CROSBI ID 209241)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Grassi, Laura ; Forneris, Jacopo ; Torresi, D ; Acosta, Luis ; Di Pietro, Alessia ; Figuera, Pierpaolo ; Fisichella, Maria ; Grilj, Veljko ; Jakšić, Milko ; Lattuada, Marcello et al. Study of the inter-strip gap effects on the response of Double Sided Silicon Strip Detectors using proton micro-beams // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 767 (2014), 99-111. doi: 10.1016/j.nima.2014.08.009

Podaci o odgovornosti

Grassi, Laura ; Forneris, Jacopo ; Torresi, D ; Acosta, Luis ; Di Pietro, Alessia ; Figuera, Pierpaolo ; Fisichella, Maria ; Grilj, Veljko ; Jakšić, Milko ; Lattuada, Marcello ; Mijatović, Tea ; Milin, Matko ; Prepolec, Lovro ; Skukan, Natko ; Soić, Neven ; Tokić, Vedrana ; Uroić, Milivoj

engleski

Study of the inter-strip gap effects on the response of Double Sided Silicon Strip Detectors using proton micro-beams

Double Sided Silicon Strip Detectors (DSSSDs) are segmented silicon detectors widely used for the detection of charged particles. When a charged particle hits the gap between two adjacent strips, a signal, different from the full energy one, can be generated, resulting in an incorrect energy information. With the purpose of studying inter-strip effects on the detector response, an experiment was performed using a proton micro- beam. The response of two DSSSDs, 75 and 998 μ m thick, was measured as a function of the proton impact position, beam energy and bias voltage using a low intensity proton micro-beam of about few hundred particles per second (pps). Results show that the effective width of the inter-strip region, which in turn is related to the efficiency for full energy detection, varies with both detected energy and bias voltage. The experimental results are interpreted within a simplified model.

Strip detector; DSSSD; Inter-strip gap; Proton micro-beam