Effect of temperature on post-cure polymerization of bulk-fill composites

Objectives: To investigate the 24 h post-cure polymerization and the effect of temperature on the post-cure polymerization of one conventional and three bulk-fill composite materials. Methods: A conventional composite GrandioSO (GR) and three bulk-fill composites: Tetric EvoCeram Bulk Fill (TECBF), Quixfil (QF) and X- tra fil (XF) were investigated. The samples were cured for 20 s with irradiance of 1090 mW/cm2. Composite samples were divided into two groups: the ‘‘room-temperature’’ group (RT, n = 5) and the ‘‘body-temperature’’ group (BT, n = 5) and they were stored in dark at 20 8C and 37 8C, respectively. Measurements of degree of conversion (DC) were made immediately after curing (0 h) and 24 h post-cure (24 h). To analyse the extent of post-cure DC increase, the DC values of 0 h-RT/24 h-RT and 0 h-BT/24 h-BT were compared. To analyse the difference in DC between RT and BT, the DC values of 0 h- RT/0 h-BT and 24 h-RT/24 h-BT were compared. Results: DC increase 24 h post-cure was significant for all composites and ranged between 6.3% and 8.2% in RT and between 12.5% and 15.7% in BT. All composites demonstrated a higher DC in 24 h-BT compared to 24 h-RT. The difference was statistically significant for GR, TECBF and QF. Conclusions: All composites demonstrated a significant post-cure effect after 24 h. Post- cure temperature increase from 20 8C to 37 8C yielded a higher post-cure DC increase. Clinical significance: Due to the temperature effect on the final DC, studies performed at composite samples at room temperature may record more inferior properties than these attained in the oral cavity.

Resin composite ; temperature ; raman spectroscopy ; polymerization kinetics ; methacrylate ; degree of conversion

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

42 (10)

2014.

1255-1260

objavljeno

0300-5712

10.1016/j.jdent.2014.08.004

Povezanost rada

Fizika, Dentalna medicina

Poveznice
Indeksiranost