Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Digital Dosemeter - ALARA OD - Personal Monitoring Assembly and Environmental (CROSBI ID 481671)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Prlić, Ivica ; Radalj, Željko ; Cerovac, Zdravko ; Marović, Gordana ; Gladić, Jadranko ; Vrtar, Mladen ; Senčar, Jasminka ; Cerovac, Hrvoje ; Digital Dosemeter - ALARA OD - Personal Monitoring Assembly and Environmental // IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH / Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. (ur.). Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,, 2001. str. 204-204-x

Podaci o odgovornosti

Prlić, Ivica ; Radalj, Željko ; Cerovac, Zdravko ; Marović, Gordana ; Gladić, Jadranko ; Vrtar, Mladen ; Senčar, Jasminka ; Cerovac, Hrvoje ;

engleski

Digital Dosemeter - ALARA OD - Personal Monitoring Assembly and Environmental

The importance of prompt dose reporting rises when dose is received within short-time interval or when the radiation source suffers technical failures. New dosimetry concept, where radiation exposure is recognized as a private /or/ group hazard of each person involved in occupational ionizing sources handling, taking into account actual radiation quality of the source, based among other principles, on the principle of establishing the well defined controlled area is introduced.New digital dosemeter device, produced by ALARA Instruments Ltd., measures small occupational doses, including the background. Device is based on ionizing GM tube, a set of modern EEPROM memory chips and Li compound battery set. It operates in two modes and the measurements are continuously performed no matter which mode is on. First mode integrates the dose (including background). If user, or dosemeter device, enter the higher radiation field area second mode will separately start to measure the dose which is at least two times higher than the surrounding background. The level above which the higher field is considered has to be preprogrammed during the calibration of device. Level depends on the workplace type /or/ environmental conditions where the device will be used.Device is suitable ass well for the low level measurements and for the high radiation outputs. When used in the stronger fields, several devices can form a field monitoring system. Device is suitable for the various non-occupational purposes also. With some telecommunication electronics and technical improvement, this device is usable as a point (Ort) environmental measuring station. Probe is sensitive to the background radiation and is fast enough to record any change in normal environmental radiation field, send the data to the central station and raise alarm if necessary. We have built a prototype for environmental monitoring connectable to any kind of telecommunication net.

External Dosimetry; Digital dosemeters; Quality Assurance; Radiation Protection

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

204-204-x.

2001.

objavljeno

Podaci o matičnoj publikaciji

Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I.

Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,

Podaci o skupu

IPRA Regional Congres on Radiation Protection in Central Europe

poster

20.05.2001-25.05.2001

Dubrovnik, Hrvatska

Povezanost rada

Javno zdravstvo i zdravstvena zaštita