Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Quality Control in Interventional Diagnostic Radiology external dosimetry - digital dosemeters (CROSBI ID 481673)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Prlić, Ivica ; Radalj, Željko ; Cerovac, Zdravko ; Tonković, Vedran ; Terček, Vladimir ; Quality Control in Interventional Diagnostic Radiology external dosimetry - digital dosemeters // IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH / Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. (ur.). Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,, 2001. str. 62-62-x

Podaci o odgovornosti

Prlić, Ivica ; Radalj, Željko ; Cerovac, Zdravko ; Tonković, Vedran ; Terček, Vladimir ;

engleski

Quality Control in Interventional Diagnostic Radiology external dosimetry - digital dosemeters

The measurements we wish to present were performed according to new dosimetric philosophy concept where radiation exposure is recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the diagnostic radiology imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final, image evaluation quality. If seen during the interventional radiology procedures these elements are to be considered with a different weight as in common diagnostic. A team performing the intervention is directly occupationaly exposed and the radiologist is the person which has to fulfill the diagnostic-evaluation of diagnostic radiology images in real time. Real time means that the decisions depend just on considering the real time diagnostic image on the x-ray equipment monitor. In this paper we will show how the Quality Control measurements and the use of digital dosemeter with direct readout and memory options for external dosimetry/environmental monitoring can be used to establish the occupational dose delivered to the staff and dose delivered to the patient for the known diagnostic-interventional procedure. The private/group hazard will be discussed and methodology of introducing the measurements in radiographers daily work will be introduced.

External dosimetry; Digital dosemetres; ESD; Quality Control; Radiation Protection; Medical physics

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

62-62-x.

2001.

objavljeno

Podaci o matičnoj publikaciji

Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I.

Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,

Podaci o skupu

IPRA Regional Congres on Radiation Protection in Central Europe

poster

20.05.2001-25.05.2001

Dubrovnik, Hrvatska

Povezanost rada

Javno zdravstvo i zdravstvena zaštita