Energy recovery by pinch technology (CROSBI ID 93154)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Matijašević, Ljubica ; Otmačić, Helena Energy recovery by pinch technology // Applied thermal engineering, 22 (2002), 4; 477-484. doi: 10.1016/S1359-4311(01)00098-9

Podaci o odgovornosti

Matijašević, Ljubica ; Otmačić, Helena

engleski

Energy recovery by pinch technology

This paper shows how the application of pinch technology can lead towards great energy savings. The heath exchanger network of a nitric acid plant has been studied and it was found that it is possible to reduce requirements for cooling water and medium pressure steam: In order to enable these savings, three heath exchangers should be replaced with new ones: Energy consumption in steam power system increases slightly. However, the final result is a reduction of energy costs and a payback time of 14.5 months

energy recovery ; Pinch technology ; HEN design ; nitric acid plant

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

22 (4)

2002.

477-484

objavljeno

1359-4311

1873-5606

10.1016/S1359-4311(01)00098-9

Povezanost rada

Kemijsko inženjerstvo

Poveznice
Indeksiranost