Minažek, Krunoslav ; Mulabdić, Mensur Determination of Reinforced Soil Stiffness by Static Plate Load Test // Proceednigs of 10th International Conference on Geosynthetics 21 to 25 Sept Berlin / Martin Ziegler, Gerhard Brau, Georg Heerten, Kirsten Laackmann (ur.). Essen: German Geotehnical Society, 2014

Podaci o odgovornosti

Minažek, Krunoslav ; Mulabdić, Mensur

engleski

Determination of Reinforced Soil Stiffness by Static Plate Load Test

Roads and railways are always limited in the amount of allowed settlement. When soil reinforcement is used in these structures several positive effects can be achieved, including reduction of settlement and increased bearing capacity. However, the methods of testing that would offer evidence of soil improvement are difficult to perform in situ, and so far have shown limited confidence in rating rein- forcement effects. These methods should preferably be known in regular road construction practice and should be capable of reflecting presence and positive effects of soil reinforcement. The static plate load test is in common use for determination of soil vertical modulus and it seems to satisfy the mentioned requirements. This article describes the model testing that was performed on both unreinforced and reinforced natural rounded gravel. The plate load test was used to verify whether this test can give evidence of improvement of soil reinforced by geogrids. Variations in test procedures, soil layer thickness and stiffness above and below reinforced section, geogrid type, and method of soil compaction regarding detection of reinforcing effects were analyzed. The tests were performed in the laboratory, in a modified metal big pullout apparatus box. It was shown that triangular opening grids had better improvement than square opening grids. Improvement achieved due to reinforcement was higher when soft soil was foundation soil for reinforced layer, and apparently Ev1 was more sensitive to that improvement then Ev2. Recommendations for use of static plate load test in determining soil stiffness improvement and suggestions for further research in this area are given.

soil ; reinforcement ; modulus ; stiffness ; static plate load test

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

110984

2014.

objavljeno

Podaci o matičnoj publikaciji

Proceednigs of 10th International Conference on Geosynthetics 21 to 25 Sept Berlin

Martin Ziegler, Gerhard Brau, Georg Heerten, Kirsten Laackmann

Essen: German Geotehnical Society

978-3-9813953-9-6

Podaci o skupu

10th International Conference on Geosynthetics 21 to 25 Sept Berlin

predavanje

21.10.2014-25.10.2014

Berlin, Njemačka

Povezanost rada

Građevinarstvo

Indeksiranost